Passivation of Aerospace Stainless Steel Parts with Citric …

ASTM B 117 salt spray testing for 2 to 3 hours, and then evaluated for signs of red rust. Red rust is considered a failure for passivation. In addition, the stainless steel test specimens were also examined for signs of IGA (intergranular attack) and pitting after being treated in the optimized nitric, optimized citric acid, and 3

Stainless Steel Passivation

The ASTM A967 standards help ensure quality passivation services using nitric acid immersion, citric acid immersion and electrochemical treatments. What is ASTM A967 …

ASTM A967 and AMS 2700 Standards for Passivation

ASTM A967. General industries use this standard to describe and control the passivation of stainless steel. Passivation is a process of making stainless steel more stainless than it would be if left alone. It is based on using an acid (nitric or citric) under highly controlled conditions to remove free iron particles from the surface and to help form a metal oxide …

Unpacking ASTM A967

ASTM A967 defines seven tests for verification that a suitable passive surface has been formed on the component surface. These tests are all qualitative. Although some tests can more precisely detect the amount of free iron remaining on a surface, they are meant to serve as a go, no-go test for passivation. Water immersion test.

Citric Acid Passivation for Stainless Steel | CitriSurf …

This standard is used in the aerospace industry. As with ASTM A967, it set standards for both nitric acid (Method 1) and citric acid (Method 2) immersion treatments. The Method 2 citric acid passivation standard …

Passivation | Passivation of Stainless Steel | AMS …

Passivation. of Stainless Steel. Our Passivation treatment helps reduce environmental factors like water or oxidation (rust) from compromising a stainless steel part. While being produced, iron deposits and other …

A967 Standard Specification for Chemical

Scope. 1.1 This specification covers several different types of chemical passivation treatments for stainless steel parts. It includes recommendations and precautions for …

Unpacking ASTM A967

ASTM A967/A967M – Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. This standard details effective methods to chemically remove free …

Chemical Passivation Treatments for Stainless Steel Parts1

the ASTM website. 3 Available from Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402. 4 In accordance with QQ-P-35C Notice 3, …

Chemical Passivation Treatments for Stainless Steel Parts

A 967 2 3. Terminology 3.1 Definition of Term Specific to This Standard—It is necessary to define which of the several commonly used definitions of the term passivation will be …

ASTM A967/A967M-13

Below is a technical summary of specification ASTM A967/A967M-13 from ASTM for Passivation. For more information on our full line of Passivation services please visit our passivation of stainless steel page. You can also request a quote or contact a member of our technical sales team for more information. Plate Thickness: Nitric 1 – 20-25%

Stainless Steel Passivation

The ASTM A967 passivation standard applies to the cleaning, passivation and testing of stainless steel parts. Per passivation standard, ASTM A967 requires the parts to be immediately neutralized post immersion followed by a chemical treatment to treat the surface of the part. ASTM approved tests may include:

ASTM A967 Chemical Passivation Treatment for Stainless Steel

ASTM A967 citric acid passivation treatments. The standard also allows any combination of citric acid concentration, temperature and time, provided that the passivation test criteria can be met. Specific treatments are however also specified. Solution Composition (wt %)

Passivation ASTM A380, ASTM A967, QQ-P-35C, BS EN 2516

ASTM A380 - Practice for Cleaning, Descaling and Passivating of Stainless Steel Parts, Equipment and Systems. ASTM A967 - Specification for Chemical Passivation Treatments for Stainless Steel Parts (based on US Defense Department standard QQ-P-35C) BS EN 2516 - Passivation of Corrosion Resisting Steels and Decontamination of Nickel Base …

ASSIST-QuickSearch Document Details

Passivation Treatments for Corrosion-Resistant Steel (S/S by ASTM-A967 or SAE-AMS-QQ-P-35) Scope: This specification covers the different types of passivation treatments as well as recommendations, guidance and precautions for cleaning and descaling corrosion-resistent parts, components, equipment and systems. Status: …

Nitric vs Citric Passivation Methods

A summary of the various nitric acid passivation methods per ASTM A967 is provided below: • Nitric 1: 20-25 v% Nitric Acid, 2.5 w% Sodium Dichromate, 120-130F, 20 Mins minimum • Nitric 2: 20-45 v% Nitric Acid, 70-90F, 30 Mins minimum • Nitric 3: 20-25 v% Nitric Acid, 120-140F, 20 Mins minimum

ASTM A 967/A967M : 2017 | Chemical Passivation Treatments

ASTM A 967/A967M : 2017. Current. Add to Watchlist. Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. Available format (s): Hardcopy, PDF. Language (s): English. Published date: 07-01-2017. Publisher: American Society for Testing and Materials.

Metal Plating Chart

ASTM-A967-05 01Y * Passivate Honeywell Approved ASTM-A 967 Rev 05 02 Caustic Etch 03 Bright Dip ASTM B 281 04 * Hot Dip Galvanize ASTM-A 153 C 06 * Passivate -- Type II SAE-AMS QQ-P-35C 08 * Clear Chromic Acid Anodize 09 Red Anodize -- Type II Class 2

Passivation of stainless steels – British Stainless Steel

ASTM A967 passivation treatments. This standard covers both nitric and citric acid treatments. The nitric acid treatments are similar to those identified in ASTM A380. In …

ASTM A967 Passivation Standards | Able Electropolishing

The ASTM A967 passivation standard applies to the cleaning, passivation and testing of stainless steel parts. Chemical passivation removes free iron and other surface contaminants from stainless steel parts, improving corrosion resistance. Stainless steel passivation performed to the ASTM A967 standards meets these standards by passing …

Guide to Passivation Treatments [Specific Content]

The standard ASTM-A967 covers several different types of chemical passivation treatments for stainless steel parts. Then we find that the classification is similar but a little different in details than that in …

Nitric vs. Citric Acid Passivation for Stainless Steel …

Many people ask about the differences between nitric acid and citric acid for passivating parts made of stainless steel (SS), titanium (Ti), and other alloys. Both nitric acid and citric acid are effective in passivating many …

Passivation • MicroGroup

Passivation. MicroGroup, part of TE Connectivity, offers all methods of passivating per ASTM A967. The Nitric II passivation line offers an auto-titrated nitric acid bath with triple cascading deionized water rinse. …

ASTM A 967/A967M : 2017 | Chemical Passivation Treatments

ASTM A 967/A967M : 2017. Current. Add to Watchlist. Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts. Available format (s): Hardcopy, PDF. …

ASTM A967 vs. AMS 2700? Which is the right passivation spec?

A. First question: The current ASTM versions are ASTM A380 [affil link] "Standard Practice for Cleaning, Descaling, and Passivation of Stainless Steel Parts, Equipment, and Systems" and ASTM A967 [affil link] "Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts". It is relatively easy to modify a …

Nitric vs Citric Acid Passivation

A summary of the various nitric acid passivation methods per ASTM A967 is provided below: Nitric 1: 20-25 v% Nitric Acid, 2.5 w% Sodium Dichromate, 120-130F, 20 Mins minimum. Nitric 2: 20-45 v% …

Lockheed Martin Lessons Learned Stainless Steel Passivation

QQ-P-35 has been cancelled and superseded by ASTM A967 or AMS-QQ-P-35. AMS-QQ-P-35 has been cancelled and superseded by AMS 2700. AMS-QQ-P-35 Type Superseding AMS 2700 Type II 2 VI 6 VII 7 VIII 8 Not Specified Use type appropriate for alloy, subject to purchaser acceptance. This document is written in accordance with the requirements of …

Passivation of Stainless Steel | ASTM A967, AMS 2700 & QQ-P-35

The most common stainless steel passivation specifications certified by Advanced Plating Technologies are ASTM A967, AMS 2700 and QQ-P-35. APT can also certify …

ASTM A967: Standard Passivation Treatment | ProPlate®

Rinsing – spray and/or immersion must be thorough. Drying- this must immediately follow rinsing. The standards of ASTM A967 provide specific details of the acceptable methods required for passivating stainless steel. The passivation standards listed in the ASTM document embrace a variety of potential methods and techniques.

A967/A967M Standard Specification for Chemical

Abstract. This specification covers several different types of chemical passivation treatments for stainless steel parts. The treatments are the following: immersion …

ASTM A967 vs ASTM A380

The main difference is that ASTM A967 has a higher elongation at break (10%) than ASTM A380 (8%). This means that ASTM A967 is more ductile than ASTM A380 and is better …

ASTM A967/A967M-17

ASTM International [astm] PDF Price. $57.00. Add to cart Not a Member? Find out how to get ANSI Member Discount Others Also Bought. ASTM A380/A380M-17. Standard Practice for Cleaning, Descaling, and Passivation of Stainless Steel Parts, Equipment, and Systems ASTM A967/A967M-13; Included in Packages.